Information Name: | Very early warning aspirating smoke detection system VESDA-VLP |
Published: | 2015-03-03 |
Validity: | 30000 |
Specifications: | |
Quantity: | 1000.00 |
Price Description: | |
Detailed Product Description: | ? Brand: VESDA Detection method:? Aspirated Scope:? Interior Dimensions:? 125 * 225 * 325mm humidity ≤:? 5-95% Ambient temperature:?? -40 ° C-55 ° Communication: 485 ? Power supply: 24V Type:? VLP-002 Type:? fire detector alarm sounds:? a detailed description of the sound and light VLP-012 very early aspirated air sampling smoke detectors: one, VLP-002 Overview: VLP-012 Xtralis VESDA smoke detector is a series of products to detect the core component. Using its unique detection principle, the detector sensitivity range VLP up 0.005 - 20% obs / m (0.0015 - 6.25% obs / ft). VLP detectors are "very early smoke detection and alarm equipment", which can be detected at a very early stage of a fire, the smoke from a trace to a high concentration of smoke, which are able to provide reliable detection. How does it work? Efficient aspirator air samples collected, transferred to VLP detector through the air sampling pipe network. Each intake manifold has a flow sensor to monitor the airflow changes in the sampling tube. VLP detector exhaust air sampling, and sampling the air may be vented back into the protected area. In the VLP detectors, sampling the air is transferred to the laser detection chamber. Finely filtered clean air to protect the optics from contamination detection chamber. Detection chamber using a stabilized laser source and sensors installed fine, you can make the best response to a wide range of smoke types. Status of the detector, all alarms, service and fault events, are transmitted to the monitor via VESDAnet and external systems. AutoLearn? (Self-learning) VLP detection technology uses a unique software tool that can ensure the operational status of the system to achieve the best in a variety of different environments. AutoLearn? (Self-learning) function can be monitored on the environment, sets the most appropriate alarm thresholds (Alert, Action, Fire 1 and Fire 2) during debugging, and thus the potential of fires very early detection and alarm, while avoiding false reported. Reference detector (Referencing) adopted under the "supply of fresh air" function, the use of air handling systems in a controlled environment may be affected by external contamination. Reference detector feature ensures external contamination will not be detected in the protected area's concentration on smog. The system can effectively exclude infrequent events, sustained and stable operation, to avoid false positives. Performance characteristics? Extremely wide sensitivity range? Laser smoke detection technology? 4 programmable alarm? Aspirator efficient? 4 intake manifold? Each sample tube has a flow monitoring device? Clean air barrier to protect the optics from contamination ? Replace the air filter is very convenient? 7 programmable relay? VESDAnet?? AutoLearn? (self-learning)? Referencing (reference detector)? Event log (event record)? modular design? optional flush mount two, VLP-012 Technical characteristics: Supply voltage: 18-30 VDC Power: 24VDC no display module or programming module size (length width height): 350 mm x 225 mm x 125 mm (13.8 in x 8.9 in x 4.9 in) Weight: 4.0 kg (9 lbs), including the display module and programming module IP rating: IP30 Operating Conditions: Tested to: -10 ° C to 55 ° C (14 ° to 131 ° F) detector environment: 0 ° C to 39 ° C (32 ° to 103 ° F) (recommended value) sampled air: -20 ° to 60 ° C (-4 ° to 140 ° F) Humidity: 10% 至 95% RH, non-condensing make it beyond these parameters or sampling air under normal operating conditions lasting more than 0.05% obs / m (0.015% obs / ft) and other matters to the company's offices Xtralis PtyLtd advice. Sampling pipe network: sampling tube total length: 200 m (650 ft) maximum length of a single tube: 100 m (325 ft) sampling tube design modeling software: ASPIRE2 sampling tube size:? An outer diameter of 25 mm (1 in) 21 mm inner diameter of 15 至(9/16 in to 7/8 in) coverage with local technical specifications and standards can be up to 2,000 square meters (21,500 square feet) of programmable relay: 7 relay contacts rated power 2A @ 30VDC NO / NC Cable Access : 8 x 25 mm (1 in) of knockouts in a different location cable connection: screw terminals 0.2 至 2.5 sq mm (30 至 12 AWG) alarm sensitivity range: 0.005% or 至 20% obs / m (0.0015 至 6.25 % obs / ft) alarm threshold setting range: Alert (Warning): 0.005% 至 1.990% obs / m (0.0015 至 0.64% obs / ft) Action (Action): 0.010 至 1.995% obs / m (0.0031 至 0.64% obs / ft) Fire 1 (Fire 1): 0.015 至 2.00% obs / m (0.0046 至 0.625% obs / ft) Fire 2 (Fire 2): 0.020 wt 至 20.00% obs / m (0.0062 至 6.25% obs / ft) * * UL model, limited to 12% obs / m (4% obs / ft) event record: a first-in first-out principle, can store up to 18,000 events. AutoLearn (self-learning): minimum 15 minutes, the longest 15 days, the shortest one day is recommended. During the self-learning, previously set alarm threshold will not change. Software features: Reference detectors: 4 to compensate the influence of external environmental conditions caused the alarm: Alert (warning), Action (action), Fire 1 (Fire 1) and Fire 2 (Fire 2) 2 fault alarm: Maintenance (maintenance) and Major fault (major fault) Programmable Relays: 7 Maintenance Help: Filter and flow monitoring via VESDAnet network or event record three incident reports, VLP-012 Application areas: 1, business continuity is crucial continued normal operation when the device is on the business development goals is critical? The level of service provided is very important? Xtralis VESDA very early warning smoke detection devices can emit very early warning of potential fire. This is a timely investigation and handling of the fire to win precious time, so as to avoid loss, downtime and waste due to the release of the fire suppression system caused. This is very important for the following facilities: the? Communication facilities financial data center server room utilities generating facilities clean room 2, when smoke is difficult to detect whether a strong airflow will dilute the smoke, hinder it reaches the ceiling????? smoke makes it difficult to be detected? Will be staying smoke pipes, beams or vacuum region? Whether as a result of smoke beneath a tall ceiling forming a thermal barrier layer, which is difficult to be detected? Xtralis VESDA sampling points can be arranged in the return air grille or equipment cabinet, when the smoke brought here airflow can be detected. In the large open space where you can sample points Xtralis VESDA smoke detectors arranged in a drift through the place - often at some distance below the level of the ceiling. Applies to:???? Server room clean room communications facilities warehouse atrium indoor stadium theater three times, where it is difficult to maintain proximity detectors HKCEC whether protected areas are inaccessible????? When the need to suspend the existing fire detection system for maintenance work, which is not a small business to trouble? Xtralis VESDA detector can be installed in a location easily accessible, only the sampling pipe network layout in those areas difficult to access, making maintenance easy. Ideal for the following locations:????? Under the space above the ceiling and the floor area of ??prisons and detention centers elevator ventilation ducts production area 4, the time required to detect concealed inside the building to keep the design and decoration is very important not to be destroyed ? Existing smoke detection system damage the appearance of the building is very problematic? Xtralis VESDA system can be installed using a capillary sampling tube, imperceptible to the naked eye because it's there. Detectors can be placed in a cupboard or living area. It is very suitable for the following locations:????? Modern office facilities ancient architectural heritage church prisons and detention centers prominent art galleries and museums housing 5, evacuation very difficult time building is open to the public will?? Whether here will accommodate large crowds, during the evacuation they will need extra help? Whether because of congestion or limited exports leaving the evacuation becomes very difficult? Business will cause evacuation affected by what? Xtralis VESDA very early warning system for people to provide maximum time for evacuation. This is very crucial for the following places:?????? Mall hospital architectural heritage of ancient underground tunnels stadium facilities or facilities for children aged 6, when the environmental conditions are extremely poor air quality in the protected areas is poor? The existence of extreme temperature conditions? Xtralis VESDA detector has two filters, you can ensure that it remains in good working condition in dirty environments. Moreover, the detector can be installed elsewhere, only the sampling tube disposed within the extreme environments. Air samples will be filtered before reaching the detector, heating or cooling. Ideal environment for the following:???????? Power plant mines on public transport industry mills and sawmills refrigerator production line in hazardous areas (FM, a 2) 7, when the fire extinguishing system extinguishing system released the need to spend huge sums of money and damage? Xtralis VESDA very early warning provided by the system allows you to deal with the fire as soon as possible, and take effective measures had to start before the fire extinguishing system. Xtralis VESDA system can use a multi-level alarm, from the air conditioner to control the release of the fire suppression system, to trigger different responses in different stages of a fire. Can be used in the following areas:???? Communication network center server room dispatching station switchgear room |
Admin>>>
You are the 6601 visitor
Copyright © GuangDong ICP No. 10089450, Ting Yang Technology Co., Ltd. of Shenzhen City All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 6601 visitor
Copyright © GuangDong ICP No. 10089450, Ting Yang Technology Co., Ltd. of Shenzhen City All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility